Hazard definitions

The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels 
or to important information concerning the life of the product.

 DANGER

 WARNING

 CAUTION

 CAUTION

 NOTICE

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious 
injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or 
serious injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or 
moderate injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not 
avoided, may result in property damage.

NOTICE indicates special instructions on installation, operation, or maintenance that are important but 
not related to personal injury or property damage.

Contents

HAZARD DEFINITIONS .....................................................  2
PLEASE READ BEFORE PROCEEDING .........................  3
1.  PREVENT COMBUSTION AIR CONTAMINATION .....  4
2.  MAINTENANCE SCHEDULE .......................................  5
Maintenance Procedures ...................................................  6
     Boiler Must Be Serviced and Maintained ....................  6
     Check Boiler Area .........................................................  6
     Check Pressure Temperature Gauge ...........................  6
     Check Vent Piping ........................................................  6
     Check Air Piping ...........................................................  6
     Check Relief Valve .......................................................  6
     Check Condensate Drain System ................................  6
     Test Low Water Cutoff (if installed) ..............................  7
     Reset Button (low water cutoff) ....................................  7
     Check Boiler Piping (gas and water) ............................  7
     Operate Relief Valve ....................................................  7
     Shut Boiler Down ..........................................................  7

3.  OPERATING INSTRUCTIONS .....................................  8
4.  SMART TOUCH CON•X•US INTERFACE
     Power-fin CON•X•US Interface .....................................  9
     Home Screen ................................................................  9
Revision Notes ................................................... Back Cover

Summary of Contents for Power-fin 1002

Page 1: ...er s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the i...

Page 2: ...tially hazardous situation which if not avoided may result in property damage NOTICE indicates special instructions on installation operation or maintenance that are important but not related to perso...

Page 3: ...er can cause internal corrosion in system components Leaks in boiler or piping must be repaired at once to prevent the need for makeup water Freeze protection fluids NEVER use automotive antifreeze Us...

Page 4: ...s Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishments New building cons...

Page 5: ...nd flame sense electrodes sand off any deposits clean and reposition Check wiring and connections Perform start up checkout and performance verification per Section 9 Flame inspection stable uniform C...

Page 6: ...will cause significant damage to the boiler if allowed to continue Read the list of potential materials listed in Table 1A on page 4 of this manual If any of these products are in the room from which...

Page 7: ...wn boilers used for domestic water heating they must operate year round 3 Replace the front access door Test low water cutoff if installed 1 If the system is equipped with a low water cutoff test the...

Page 8: ...call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety...

Page 9: ...e bottom right of the screen and displays both factory installed and field installed sensor including Outdoor Air Hot Water Temperature System Supply System Return Inlet Water Delta T Outlet Water Flu...

Page 10: ...10 Notes User s Information Manual...

Page 11: ...11 Notes User s Information Manual...

Page 12: ...reflects an update to the maintenance information for the service technician on page 5 Revision C PCP 3000028200 CN 500017830 reflects an update to the Home Screen information Revision D PCP 300003085...

Reviews: