background image

-- Do not store or use gasoline or other flammable vapors and 
liquids in the vicinity of this or any other appliance.

-- 

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your 
 building.
• Immediately call your gas supplier from a near by phone. 

 

  Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
-- Installation and service must be performed by a qualified 
    installer, service agency, or the gas supplier.

WARNING:

   

If the information in these instructions is 

not followed exactly, a fire or explosion may result causing 
property damage, personal injury or death.

100280637_2000538994_Rev D

User’s Information Manual

Models:  502, 752, 1002, 1302, 

1501, 1701, and 2001

Up To 5:1 Turndown

Beginning with 

Serial # 1707104971206

Save this manual for future reference.

Summary of Contents for Power-fin 1002

Page 1: ...er s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the i...

Page 2: ...tially hazardous situation which if not avoided may result in property damage NOTICE indicates special instructions on installation operation or maintenance that are important but not related to perso...

Page 3: ...er can cause internal corrosion in system components Leaks in boiler or piping must be repaired at once to prevent the need for makeup water Freeze protection fluids NEVER use automotive antifreeze Us...

Page 4: ...s Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishments New building cons...

Page 5: ...nd flame sense electrodes sand off any deposits clean and reposition Check wiring and connections Perform start up checkout and performance verification per Section 9 Flame inspection stable uniform C...

Page 6: ...will cause significant damage to the boiler if allowed to continue Read the list of potential materials listed in Table 1A on page 4 of this manual If any of these products are in the room from which...

Page 7: ...wn boilers used for domestic water heating they must operate year round 3 Replace the front access door Test low water cutoff if installed 1 If the system is equipped with a low water cutoff test the...

Page 8: ...call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety...

Page 9: ...e bottom right of the screen and displays both factory installed and field installed sensor including Outdoor Air Hot Water Temperature System Supply System Return Inlet Water Delta T Outlet Water Flu...

Page 10: ...10 Notes User s Information Manual...

Page 11: ...11 Notes User s Information Manual...

Page 12: ...reflects an update to the maintenance information for the service technician on page 5 Revision C PCP 3000028200 CN 500017830 reflects an update to the Home Screen information Revision D PCP 300003085...

Reviews: