80
reserved[3]
k64s
Reserved for internal use
issues[issueCount]
k64s
Issue list (defined below)
Calibration Issue
Field
Type
Description
groupId
k64s
Group identifier (0-Top, 1-Bottom).
columnId
k64s
Camera location in group (index).
deviceId
k64s
Sensor identifier (serial number).
bankId
k64s
Camera location in sensor (0-Left, 1-Right).
sourceType
k64s
Camera type (0-Profile, 1-Vision, 2-Tracheid).
x0
k64s
Left x-coordinate for this issue (mils).
x1
k64s
Right x-coordinate for this issue (mils).
activity
k64s
Calibration activity associated with issue:
Profile (0)
Profile Y (1)
Profile Z (2)
Vision (1000)
Vision X (1001)
Vision Y (1002)
Vision Gain (1003)
Tracheid (2000)
status
k64s
Calibration issue type:
Warning (1000)
Warning Frame Loss (1003)
Warning Insufficient Data (1004)
Warning Intensity Too High/Low (1007)
Error (2000)
Error Prerequisite Not Satisfied (2001)
Error Algorithm (2002)
Error Frame Loss (2003)
Error Insufficient Data (2004)
Error Feature Not Found (2005)
Error Noise (2006)
Error Intensity Too High/Low (2007)
reserved[2]
k64s
Reserved for internal use
7.4.3
Web Mode
In
Web
mode, the server applies calibration transformations and resamples data to the
requested output resolutions, but does not attempt to detect discrete objects. Three
different types of message can be transmitted by the server:
Web Mode Profile Message
(11),
Web
Mode Vision Message
(12), and
Web Mode Tracheid Message
(13). Profile
messages contain geometric measurements captured using lasers and profile cameras.
Tracheid messages contain spot angle, scatter, and area measurements captured using
lasers and tracheid cameras (if present). Vision messages contain image pixels captured
using LEDs and vision cameras (if present). Each message contains measurement data
for a fixed interval along the y-axis, determined by the
Sampling/TileWidth
setting. A
fourth message type,
Encoder Message
(15), can be enabled by setting the field
EncoderBatchSize
in the server settings file (
Settings.xml
) to a non-zero value. This
message contains batched encoder and timestamp readings at the profile speed for
accurate encoder diagnostics. The batch size is set through the server settings file (see
Summary of Contents for chroma+scan 3155
Page 1: ...chroma scan 3x00 Document Version 4 11 12 30...
Page 14: ...14 3 1 1 Sensors chroma scan 3155 chroma scan 3250 chroma scan 3350...
Page 31: ...31 5 5 Dimensions and Mounting 5 5 1 chroma scan 3155 Sensor Dimensions...
Page 32: ...32 5 5 2 chroma scan 3250 Sensor Dimensions...
Page 33: ...33 5 5 3 chroma scan 3350 Sensor Dimensions...