35
Section 6
6 System
6.1 Overview
A scan 3x00 system consists of some or all of the following components:
scan 3155, 3250 or 3350 sensors
FireSync Master 1200 or Master 2400
User-supplied Station PC(s)
FireSync Cordsets
Power Supply
Encoder
Client Computer
Scanner Frame
System Calibration Target
Power and Encoder Wiring
In a typical system, up to 24 scan 3x00 sensors are placed top-and-bottom and
end-to-end along the length a scanner frame. However, in some systems the bottom
sensors may be omitted if mechanical constraints of the chain design prevent mounting
sensors there.
The Master is the central hub of the system, and provides power, encoder, Safety
Interlock, and digital I/O routing. Each sensor and the encoder connect to the Master via
sensor cordsets. The power supply provides power to the Master and FireSync Station
(if applicable). The Master distributes power to the sensors and encoder. A single
CAT5E Gigabit Ethernet cable provides the communication link from the Station to the
Client computer.
The FireSync Master 1200 supports 12 sensors while the FireSync Master 2400
supports 24 sensors
A server application, running on the Station, integrates data from the encoder and
sensors, and transmits the processed output to the client.