Little Giant 10E Series Manual Download Page 2

Form 994343 — 05/2001

www.LittleGiantPump.com

10E Series

Specifications

Construction

Model  

No.

Item No.

Listing

HP

Volts

Solids Size

(dia. in.)

Running 

Amps/Watts

Performance (GPM@Head)

Shutoff

Cord 

Length (ft.)

Weight 

(lbs.)

Dimensions

H x L x W (in.)

5'

10'

15'

20'

Ft.

P.S.I.

10E-CIM

511200

UL/CSA

1/2

115

3/4"

10.5/900

80

67

52

33

26

11.2

15

35

10.25 x 9.6 x 8.25

10E-CIA-RFS

511300

UL/CSA

1/2

115

3/4"

10.5/900

80

67

52

33

26

11.2

15

37

10.25 x 9.6 x 8.25

10E-CIM

511275

UL/CSA

1/2

208-230

3/4"

6.6A/900

80

67

52

33

26

11.2

15

36

10.25 x 9.6 x 8.25

10E-CIM

511225

UL/CSA

1/2

115

3/4"

10.5/900

80

67

52

33

26

11.2

25

36

10.25 x 9.6 x 8.25

All Models are 60 Hz                            (NOTE: Use 6.5 amps for 511275 for 50 Hz rating)

RFS= Mechanical Float Switch

Motor Housing

Epoxy coated cast iron

Impeller Material

Nylon

Impeller Type

Vortex

Volute

Epoxy coated cast iron

Power Cord

SJTW-A

Mechanical Shaft Seal

Nitrile with carbon and ceramic 
faces

Fasteners

Stainless steel

Shaft

Steel

Bearings

Upper and lower ball bearings

PO Box 12010 • Oklahoma City, OK 73157

Phone: 800.701.7894 • Fax: 800.701.8046

E-mail: customerservice@littlegiant.com

Summary of Contents for 10E Series

Page 1: ...filled motor housing for lifetime lubrication and rapid heat dissipation n Stainless steel fasteners n Mechanical seals stainless steel spring nitrile parts Carbon and ceramic faces n Bearings Upper...

Page 2: ...11275 UL CSA 1 2 208 230 3 4 6 6A 900 80 67 52 33 26 11 2 15 36 10 25 x 9 6 x 8 25 10E CIM 511225 UL CSA 1 2 115 3 4 10 5 900 80 67 52 33 26 11 2 25 36 10 25 x 9 6 x 8 25 All Models are 60 Hz NOTE Use...

Page 3: ...splice between the pump and the control panel must be made within a junction box and mounted outside of the basin and comply with the National Electrical Code Do not use the power cord for lifting the...

Page 4: ...33 26 11 2 15 36 10E CIM UL CSA 1 2 208 240 3 4 6 5 900 80 67 52 33 26 11 2 15 36 10E CIA RFS UL CSA 1 2 115 3 4 10 900 80 67 52 33 26 11 2 15 36 10S CIM UL CSA 1 2 115 2 12 1000 110 85 45 20 8 7 15 4...

Page 5: ...nect plastic pipe to pump Pump must be placed on a hard level surface Never place pump directly on clay earth or gravel surfaces A check valve must be used in the discharge line to prevent back flow o...

Page 6: ...rci afin qu il entre dans un panneau de commande Toute pissure entre la pompe et le panneau de commande doit tre faite l int rieur d une bo te d accouplement et install e hors du r servoir elle doit a...

Page 7: ...n 4 AVERTISSEMENT LAISSEZ LA TURBINE EN PLACE LE RETRAIT DE LA TURBINE N CESSITE DES OUTILS SP CIAUX ET NE PEUT TRE EFFECTU QU UN CENTRE DE SERVICE AUTORIS LAISSER LE COUVERCLE DU BO TIER DU MOTEUR EN...

Page 8: ...producto Guarde las instrucciones para referencia futura El producto que ha adquirido se fabrica utilizando mano de obra y materiales de la m s alta calidad y ha sido dise ado para prestarle un servi...

Page 9: ...ta el enchufe o se acorta el cable la garanti ser nula 3 Si el cable viene dotado de hilos conductores forrados como ocurre en los modelos de 230 voltios cerci rese de que los hilos conductores se enc...

Page 10: ...go El ctrico Nacional NEC m s reciente Para ajustarse a las disposiciones del C digo El ctrico Nacional todas las bombas deben tener cables 14 AWG o mayores Para recorridos 250 pies basta el cable de...

Page 11: ...6 6 5 951964 Lead Wire Red 1 1 1 1 1 1 1 1 6 901306 Screw 6 32 x 3 16 3 3 3 3 3 3 3 3 7 951963 Lead Wire Black 1 1 1 1 1 1 1 1 8 950930 Relay 115V 1 1 1 1 1 8 950934 Relay 230V 1 1 1 9 928019 Seal Rin...

Page 12: ...abierto resistencia infinita cerrado cero Loose connection in level control wiring Connexion des fils lectriques du niveau de contr le distendue Conexiones flojas en los cables del regulador de nivel...

Page 13: ...of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state...

Page 14: ...uesto a acci n judicial por el costo de mano de obra externa en el lugar u otros cargos incurridos por cualquier cliente al extraer o asegurar cualquier producto LITTLE GIANT pieza o componente de ste...

Reviews: