Page 20
7.0 Troubleshooting
A general guide to troubleshooting is to consider the system as separate elements, such as:
- Power distribution within the Litile34 modules
- Video Scaler / MDU controller settings
- Cabling (CAT 7 cables from MDU to modules)
- Computer system (display settings, operating system)
No Image
If the fluorescent lamps are not powered on it may still be possible to see a faint image on
the display. A complete lack of image is most likely to be caused by incorrect connection,
lack of power, failure to provide a signal or incorrect MDU / Scaler settings
Scramble Screen
This occurs when the MDU setting and the output resolution setting on the scaler do not
match. Refer to settings table to match the MDU and scaler settings required.
Power Cord
Due to the high power consumption needed for the system, please make sure to use the
original power cord as supplied to prevent the overheat issue.
Image Position
If the image does not appear in the correct position on the screen, the settings on the scaler
unit will need to be adjusted.
Image Appearance
If a single litile34 shows blank or coloured vertical lines, failed sections, flickering or flashing
display, this can indicate a damaged cable or LCD panel. Contact Customer Support at
Litemax for assistance.
LiTile34
In case of physical damage to the Litile34 requiring replacement, please contact
customer support at Litemax.