4
Maintenance and service
Liquiflo FTS Transfer Pump User Manual
Series No. FTS300
26
Center plate seal and replacement, bearing replacement, and reassembly
5.
Remove the center plate inner shaft seals using a seal removal tool, hooking it under the lip of each seal and gently
prying upward, Figure 5.
6.
Be sure you are using shaft seal number 1000-1750, Figure 6. Position the shaft seals with the cup facing
down
,
and push firmly into place.
7.
If bearings are to be replaced - Using an ID bearing puller, extract both sets of bearings from the bearing plate,
Figure 7. With the bearing plate on a firm, flat surface, press new bearings into bearing plate until they are flush
with bearing cavity face, Figure 8.
Continued on next page
Lubricate the inner lips of the shaft seals with Mobilgrease XHP
™
222.
Figure 5
Shaft seals
Figure 6
Figure 7
1.00” x 1.00” bearings
Figure 8
bearings flush with this surface