4
Maintenance and service
Liquiflo FTS Transfer Pump User Manual
Series No. FTS300
17
Removing gear chamber from center plate and pump chamber
1.
Using a 6 mm hex key, remove the eight M8 x 40 mm socket head cap screws that attach the gear chamber and
center plate to the pump housing, Figure 1.
2.
Carefully pull the gear chamber to remove it from the center plate, Figure 2.
3.
If the gear chamber sticks to the center plate, find the pry slot on the center plate, Figure 3, and insert a pry bar or
other tool to gently loosen the gear chamber from the center plate.
Figure 1
Figure 2
Figure 3
Eight M8 screws
Gear chamber pry slot
Gear chamber pry slot