background image

Installation Guide Power Supply 

 

ENG 

NTI AG / LinMot 

Power range 1000 W 

Page 3 / 12 

1  General information 

1.1  Introduction 

Please observe the following safety instructions, the instructions on the appliance (the term "appliance" 
relates to a single power supply assembly) and the detailed data sheet to avoid any risk of personal injury or 
damage to the appliance or to other equipment which may be connected. 

1.2  Explanation of symbols 

 

Triangular warning symbols warn against a danger. 

 

 

Round command symbols tell what to do. 

1.3  Qualified personnel 

All work such as transport, installation, commissioning and service is only allowed to be carried out by 
qualified personnel. Qualified personnel in the sense of the safety instructions in this documentation are 
persons who are familiar with the transport, installation, assembly, commissioning and operation of the 
product and who have the appropriate qualifications. 
This manual must be read carefully before transport, installation, commissioning, service and all safety-
related information must be adhered to. 

1.4  Liability 

NTI AG (as manufacturer of LinMot linear motors and MagSpring products) excludes all liability for damages 
and expenses caused by incorrect use of the products. This also applies to false applications, which are 
caused by NTI AG's own data and notes, for example in the course of sales, support or application activities. 
It is the sole responsibility of the user to check the information and information provided by NTI AG regarding 
their safety-relevant correctness. In addition, the entire responsibility for safety-related product functionality 
lies exclusively with the user.Product warranties are void if products are used with stators, sliders, servo 
drives or cables not manufactured by NTI AG unless such use was specifically approved by NTI AG. 
NTI AG’s warranty is limited to repair or replacement as stated in our standard warranty policy as described 
in our "terms and conditions" previously supplied to the purchaser of our equipment (please request copy of 
same if not otherwise available). Further reference is made to our general terms and conditions. 

1.5  Copyright 

This work is protected by copyright. 
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or 
mechanical, including photocopying, recording, microfilm, storing in an information retrieval system, not even 
for training purposes, or translating, in whole or in part, without the prior written consent of NTI AG. 
LinMot® is a registered trademark of NTI AG. 

 

 

Summary of Contents for S01-72/1000

Page 1: ...NTI AG LinMot Dok Nr 0185 0077 E_2V1_IG_Power_Supplies_S01_72_1000 Installation Guide Power Supply ENG Power range 1000 W Type S01 72 1000 ...

Page 2: ...Liability 3 1 5 Copyright 3 2 Safety instructions 4 3 Technical Data 5 4 Operating data 6 5 Mechanics 6 5 1 Connection 6 5 2 Mounting 7 6 Explanation of symbols 7 7 Notes 8 7 1 Context between powerboost time and minimum break time 8 7 2 Current limiting characteristic 8 8 Dimensions 9 9 International Certificates 9 10 Declaration of Conformity and CE marking 10 11 CB Test Certificate 11 ...

Page 3: ...ages and expenses caused by incorrect use of the products This also applies to false applications which are caused by NTI AG s own data and notes for example in the course of sales support or application activities It is the sole responsibility of the user to check the information and information provided by NTI AG regarding their safety relevant correctness In addition the entire responsibility f...

Page 4: ...liance To ensure safe performance and avoid any possible risk of damage to the assembly itself and or connected equipment provision must be made for adequate heat dispersal Please observe the relevant instructions in this document and the appliance Please take note of the information shown on the connection and pin configurations for this appliance Pay particular attention to the information on th...

Page 5: ...se voltage 200mVss typ Temperature coefficient 0 025 K Switch on switch off No Vo overshoot soft start Start up delay 250 ms typ Rise time 20ms typ 155ms typ bei 50 000 μF Last Back feeding voltage approx 100VDC Serial connection yes max 2 identical power supplies Parallel connection yes max 3 identical power supplies Regelung Line regulation 0 3 for Vo at Uemin Uemax Load regulation 0 5 for Vo at...

Page 6: ...4 3 EN 55022 EN 55011 class B Radiation depends on assembly Weight 2 0 kg 4 Operating data Temperature range 25 C 70 C integral temperature controlled fan air intake bottom up fan swichted on off in two steps dependent on temperature Derating 2 K at 60 C Operation in any assembly position possible The distance between the surrounding components and the air admission and air exit holes should be at...

Page 7: ... any assembly position possible The distance between the surrounding components and the air admission and air exit holes should be at least 50 mm Please ensure that exhaust air is not immediately sucked in again 6 Explanation of symbols PE Protective conductor Do not use supply without PE connection L1 L2 L3 Mains phases Load connection Relay OK FAIL Monitoring connections OFF Control connection ...

Page 8: ... AG LinMot 7 Notes 7 1 Context between powerboost time and minimum break time 7 2 Current limiting characteristic Start up takes place with power boost between 190 and 210 of the nominal current for a period of approx 2s You can use power boost also in running operation ...

Page 9: ...Installation Guide Power Supply ENG NTI AG LinMot Power range 1000 W Page 9 12 8 Dimensions in mm 9 International Certificates ...

Page 10: ... 72V 1000W 3x340 550VAC 0150 1872 konform ist mit den Anforderungen der Richtlinien is conform to the provisions of directives est conformé aux exigences des directives 2014 35 EU LVD 2014 30 EU EMCD gestützt auf die folgenden Normen based on the following standards base aux normes suivants EMCD EN61000 6 2 2005 EN61000 6 3 2007 A1 2011 SAFETY IEC 60950 1 2005 second edition A1 2009 A2 2013 EN 609...

Page 11: ...Installation Guide Power Supply ENG NTI AG LinMot Power range 1000 W Page 11 12 11 CB Test Certificate ...

Page 12: ...kerstrasse 2 CH 8957 Spreitenbach Sales Administration 41 0 56 419 91 91 office linmot com Tech Support 41 0 56 544 71 00 support linmot com Tech Support Skype skype support linmot Fax 41 0 56 419 91 92 Web http www linmot com LinMot USA LinMot USA Inc N1922 State Road 120 Unit 1 Lake Geneva WI 53147 Sales Administration 262 743 2555 E Mail usasales linmot com Web http www linmot usa com ...

Reviews: