Installation Guide Power Supply 

 

ENG 

Page 4 / 12 

Power range 1000 W 

NTI AG / LinMot 

2  Safety instructions 

 

Do not open! 
Do not use without a PE connection. 
Disconnect power before installing or removing. 
For built-in use only! 
 
This warning also applies in the event that an internal fuse blows in the appliance. 
The appliance should generally only be opened and/or repaired by the manufacturer. 

 

 

Appliances are approved for operation based on the connected loads and technical data 
stated on the rating plate and the detailed data sheet only. Please read these carefully 
before installing the appliance and commencing operation and take note of any 
performance limitations, such as reduced output power (derating) in the event of high 
ambient temperatures. 

 

 

All appliances must be connected to a mains supply offering voltage quality which complies 
with EN50160 standards. Operating the appliance via UPSs, current inverters etc. which do 
not meet these standards may result in damage to the appliance. In such cases, no 
guarantee claims will be accepted. 

 

 

As a rule, appliances are intended for built-in use. They must be installed and connected by 
qualified personnel. 

 

 

Ensure that the surrounding casing protects the appliance against fire! 

 

 

Heat loss occurs during operation of the appliance. To ensure safe performance and avoid 
any possible risk of damage to the assembly itself and/or connected equipment, provision 
must be made for adequate heat dispersal. Please observe the relevant instructions in this 
document and the appliance. 

 

 

Please take note of the information shown on the connection and pin configurations for this 
appliance! Pay particular attention to the information on the wire cross-section and torque 
and ensure that the wiring complies with prevailing standards. 

 

 

If a load output is designed to take sensor cables, these must be connected to the 
corresponding load lines to ensure safe operation of the appliance. 

 

 

Appliances may be connected in parallel if this option is given in the technical data; max. 
three identical appliances, otherwise please consult LinMot. Advice should normally be 
obtained from LinMot before connecting appliances in series. 

 

 

Trim potentiometers may not be used on appliances unless the relevant setting range is 
given in the technical data and on the appliance, and the maximum output power is not 
exceeded. 

 

 

All appliances have been tested for compliance with the prevailing insulation and high-
voltage standards. Any additional tests of this kind which may be required should not be 
carried out without the consent of the appliance manufacturer, LinMot. As there could be a 
potential risk of damaging or destroying components in the appliance, it may be necessary 
to take special precautions prior to such tests. 

 

 

Summary of Contents for S01-72/1000

Page 1: ...NTI AG LinMot Dok Nr 0185 0077 E_2V1_IG_Power_Supplies_S01_72_1000 Installation Guide Power Supply ENG Power range 1000 W Type S01 72 1000 ...

Page 2: ...Liability 3 1 5 Copyright 3 2 Safety instructions 4 3 Technical Data 5 4 Operating data 6 5 Mechanics 6 5 1 Connection 6 5 2 Mounting 7 6 Explanation of symbols 7 7 Notes 8 7 1 Context between powerboost time and minimum break time 8 7 2 Current limiting characteristic 8 8 Dimensions 9 9 International Certificates 9 10 Declaration of Conformity and CE marking 10 11 CB Test Certificate 11 ...

Page 3: ...ages and expenses caused by incorrect use of the products This also applies to false applications which are caused by NTI AG s own data and notes for example in the course of sales support or application activities It is the sole responsibility of the user to check the information and information provided by NTI AG regarding their safety relevant correctness In addition the entire responsibility f...

Page 4: ...liance To ensure safe performance and avoid any possible risk of damage to the assembly itself and or connected equipment provision must be made for adequate heat dispersal Please observe the relevant instructions in this document and the appliance Please take note of the information shown on the connection and pin configurations for this appliance Pay particular attention to the information on th...

Page 5: ...se voltage 200mVss typ Temperature coefficient 0 025 K Switch on switch off No Vo overshoot soft start Start up delay 250 ms typ Rise time 20ms typ 155ms typ bei 50 000 μF Last Back feeding voltage approx 100VDC Serial connection yes max 2 identical power supplies Parallel connection yes max 3 identical power supplies Regelung Line regulation 0 3 for Vo at Uemin Uemax Load regulation 0 5 for Vo at...

Page 6: ...4 3 EN 55022 EN 55011 class B Radiation depends on assembly Weight 2 0 kg 4 Operating data Temperature range 25 C 70 C integral temperature controlled fan air intake bottom up fan swichted on off in two steps dependent on temperature Derating 2 K at 60 C Operation in any assembly position possible The distance between the surrounding components and the air admission and air exit holes should be at...

Page 7: ... any assembly position possible The distance between the surrounding components and the air admission and air exit holes should be at least 50 mm Please ensure that exhaust air is not immediately sucked in again 6 Explanation of symbols PE Protective conductor Do not use supply without PE connection L1 L2 L3 Mains phases Load connection Relay OK FAIL Monitoring connections OFF Control connection ...

Page 8: ... AG LinMot 7 Notes 7 1 Context between powerboost time and minimum break time 7 2 Current limiting characteristic Start up takes place with power boost between 190 and 210 of the nominal current for a period of approx 2s You can use power boost also in running operation ...

Page 9: ...Installation Guide Power Supply ENG NTI AG LinMot Power range 1000 W Page 9 12 8 Dimensions in mm 9 International Certificates ...

Page 10: ... 72V 1000W 3x340 550VAC 0150 1872 konform ist mit den Anforderungen der Richtlinien is conform to the provisions of directives est conformé aux exigences des directives 2014 35 EU LVD 2014 30 EU EMCD gestützt auf die folgenden Normen based on the following standards base aux normes suivants EMCD EN61000 6 2 2005 EN61000 6 3 2007 A1 2011 SAFETY IEC 60950 1 2005 second edition A1 2009 A2 2013 EN 609...

Page 11: ...Installation Guide Power Supply ENG NTI AG LinMot Power range 1000 W Page 11 12 11 CB Test Certificate ...

Page 12: ...kerstrasse 2 CH 8957 Spreitenbach Sales Administration 41 0 56 419 91 91 office linmot com Tech Support 41 0 56 544 71 00 support linmot com Tech Support Skype skype support linmot Fax 41 0 56 419 91 92 Web http www linmot com LinMot USA LinMot USA Inc N1922 State Road 120 Unit 1 Lake Geneva WI 53147 Sales Administration 262 743 2555 E Mail usasales linmot com Web http www linmot usa com ...

Reviews: