Installation Guide Power Supply
ENG
Page 6 / 12
Power range 1000 W
NTI AG / LinMot
Safety / Standards
EN 60950-1 / IEC 60950-1 / VDE 0160 safety class I / VDE 0100
/ IP20 CSA-C22.2 No 107 / CSA-C22.2 No. 60950-1-03 UL Std.
60950-1 / UL Std. 508 (Operation in Delta mains only for UL508)
EMC
Flicker
EN 61000-3-3
Interference suppression /
Interference immunity
EN 61000-6-2 / EN 61204-3
ESD
EN 61000-4-2 8/15 kV
Electrical fields
EN 61000-4-3 Noise level 10V/m
Burst
Input: EN 61000-4-4 4kV / Output: EN 61000-4-4 2kV
Surge
Input: EN 61000-4-5 2/4kV / Output: EN 61000-4-5 0,5kV
HF Immunity
EN 61000-4-6 noise level 10V
Voltage drop
EN 61000-4-11
Interference emission
EN 61000-6-3 / EN 61204-3 / EN 55022 / EN 55011 class B
Radiation depends on assembly
Weight
2.0 kg
4 Operating data
Temperature range
-25°C...70°C integral, temperature controlled fan,air intake bottom-up (fan swichted
on/off in two steps dependent on temperature)
Derating
2% / K at +60°C
Operation in any assembly position possible. The distance between the surrounding
components and the air admission and air exit holes should be at least 50 mm.
Please ensure that exhaust air is not immediately sucked in again.
Ensure that the surrounding casing protects the appliance against fire!
Protect the products against moisture, humidity, condensation and dirt.
5 Mechanics
5.1 Connection
Main input:
4-pole
1,5 - 4 mm² strand/wire
Min. tightening torque: 0,5Nm
Load output:
5-pole
2,5 - 4 mm² strand/wire
Min. tightening torque: 0,5Nm
Control signals:
4-pole
0,5 - 1,5 mm² strand/wire
Min. tightening torque: 0,22Nm