Installation Guide Linear Modules
ENG
NTI AG / LinMot
DM01-23 / 37 / 48
Page 13 / 72
3.5.3 Operating Conditions
•
Medium:
Filtered compressed air (40 µm), unlubricated or lubricated
•
Operating pressure:
4 - 6 bar
•
Ambient temperature:
10 °C…80 °C
3.5.4 Air Connection
The mounting screw leaves the spring-applied
holding brake in an open state. As soon as the
mounting screw is removed, the holding force
of the holding brake sets in. The shaft is then
clamped. Instead of the mounting screw, a
compressed air connection is now made. The
connection thread for this is G 1/8".
When pressure is applied, the brake is released
and the shaft can be moved again.
The air pressure for the brake can be controlled
by means of the LinMot servo drives and an
electric solenoid valve.
Before moving the linear module,
make sure that the brake is completely
bled!
The brake may only be actuated when
the movement is stopped!