ioPower User Guide                                                                                                               Quick Installation  

Rev. 1.41      Copyright© All rights reserved.   

Feb 2005

 

1

ioPower 

8-port Remote Power Control Unit for any AC-powered Devices / Servers 

 

Quick Installation 

 

Thank you for purchasing 

ioPower. ioPower

 can be used 

together with a host PC to control the power on/off of up to 8 
servers/AC-powered devices. With our highly reliable and 
quality product, user can enjoy countless benefits from using 
it. 
 

 

 

ioPower – Remote Power Control Unit 

 

Introduction 

 

The 

ioPower

 provides 8 AC power outlets and can be 

deployed alone with a host PC for remote power control of 
any AC-powered devices. The 

ioPower

 proves to be a 

reliable solution that offers cost-effective remote power 
control to enterprise-level customers. 
 
To control your AC-powered devices, you only need to tap 
them to any of 

ioPower

’s 8 power output outlets and then 

connect the 

ioPower

 to a host PC installed with the 

Power 

Management

 software.  To power on/off the connected AC-

powered devices, you only need to press the front-panel 
button (press and hold for 2 seconds to activate/deactivate 
power port upon button release); or you can use the power 
management software. The software is installed on a host 
PC and provides a virtual front-panel that allows user to click 
to power on/off any connected devices. It also provides timer 
function to preset the destined power on/off time or power-up 
duration for each of your devices either at specific time or for 
recurrences. 
 
The 

ioPower

 is also capable of cascading with multiple units 

into a daisy-chained configuration to maximize the port 
capacity up to one hundred more. Thus you can easily 
control up to hundred of AC-powered devices and/or servers. 

 

 

ioPower

 connected to a host PC 

You might need to use extra adapter cords between ioPower and 

your devices, especially when the devices are not of the plug 
specification that fits the standard power outlets on the backpanel of 
ioPower. 

 

Features 

 

Hardware 

 

 

Can be used alone or cascaded with multiple units for 
power control of 8 to 100 more AC-powered devices 

 

Unit management using a host PC connected via serial 
interface (RS-232)  

 

Allows full control of 8 AC power outlets using ASCII 
commands over a serial interface 

 

Cascadable up to 16 units and control up to 128 AC 
power outlets, using UTP cables over RJ-45 interfaces 

 

Last known port status of each port retained and 
optionally restored when restarted after unit power down 

 

Timer setting restored when restarted after unit power 
down 

 

Numerical display to show power unit bank number 
when in multiple cascaded application 

 

Numerical display to monitor total current loads 
(showing 0.0 ~ 15A) 

 

8 green (ON/OFF) LED indicators to show the ON/OFF 
status of each A/C power outlet  

 

8 red (Alarm) LED indicators to show the state of failure 
of each AC power outlet 

 

“One-Touch" power ON/Off control by front-panel 
buttons (with 2” time-delay for activation/deactivation 
upon button release) 

 

Internal battery to retain unit configuration and port 
status/timer settings. 

 

19" rack-mountable design with metal case  

 

ioPower

 Management Software 

 

 

Intuitive user interface with virtual front-panel, power 
buttons and LED indicators 

 

Current loads (per port/total) and bank number displays 

 

Auto-configuration of COM port 

 

Power On/Off Timer function 

 

Simultaneous Power on/off all ports of one/all banks 

 

Power On/Off confirmation dialog prompt 

 

Remote power activation/deactivation based on 
duration/specific time point/daily-weekly recurrence 
timer settings 

 

Before you install 

 
Before you connect your devices to 

ioPower

, please verify 

that the specifications are appropriate for your usage, for 
example: the output voltage should be in accordance with 
that required by your devices; and the total power loads and 
the power loads per port should not exceed the maximum 
total/per port output within its specification. Also the 
installation and operation should adhere to the local safety 
regulations. 
 
 

Summary of Contents for ioPower

Page 1: ...ioPower 8 port Remote Power Control Unit for any AC powered Devices Servers User Guide Rev 1 41 Feb 2005...

Page 2: ...with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause interference to household appliances in which case th...

Page 3: ...ioPower User Guide Table of Contents iii Table of Contents Table of Contents iii Quick Installation 1 Flash Upgrade Operation Guide Using Windows HyperTerminal 7 Serial Command Set 10...

Page 4: ...that fits the standard power outlets on the backpanel of ioPower Features Hardware Can be used alone or cascaded with multiple units for power control of 8 to 100 more AC powered devices Unit manageme...

Page 5: ...panel Rear panel for the US Region Rear panel for the EU Region You might need to use extra adapter cords between ioPower and your devices especially when the devices are not of the plug specification...

Page 6: ...front panel identical to the physical front panel If you are cascading multiple units of ioPower using the RJ 45 daisy chain interfaces connected by a UTP cable you can then see a corresponding number...

Page 7: ...ore the last known port status of each port when ioPower unit is restarted Tools Upgrade Once ioPower firmware upgrade is available you can either get it from your local dealer or download it from ava...

Page 8: ...utes to go for a Power On on all ports Note that the timer settings will also be executed nonetheless when 1 the host PC is shut down or 2 the ioPower Management Software is disconnected to the ioPowe...

Page 9: ...persistently If so it indicates that this port is malfunctioning for good and need technical service from your local dealer Port Error unable to power on Port Error unable to power off While an alarm...

Page 10: ...l computer You can copy them from the diskette CD ROM provided by the technical support or download it from available support website Check the connection between the ioPower Unit and PC Make sure you...

Page 11: ...he next step Flash Upgrade File Transfer Step 7 To start loading the file access the drop down menu on HyperTerminal Transfer Send Text File and a dialog box will prompt you to select the flash upgrad...

Page 12: ...nit Wait for a few seconds and then complete the reset again Troubleshooting If the flash upgrade procedure seems never ending or you see the following message Please send new firmware shown on the sc...

Page 13: ...require a strict double digit entry of bank number or port number such as ON 01 03 Power on bank 1 port 3 but can accept their single digit entries such as ON 1 3 and also allow multiple blank spaces...

Page 14: ...rn on off a specific port at specific time Usage TA bank_number port_number ON OF Time_point Examples TA 1 4 ON 01 22 50 Set timer to power on port 4 on bank 1 exactly at 01 22 50 TA 1 0 ON 00 10 00 S...

Page 15: ...r to power on all ports on bank 1 exactly every Wednesday at 00 10 00 EW 0 0 OF 5 01 00 00 Set timer to power off all ports on all cascaded banks every Friday at 01 00 00 Notes 1 A port number of 0 re...

Page 16: ...E Example UPGRADE Note Please also refer to ioPower Flash Operation Guide for details SETTIME Set Up System Date and Time Description Set up the system date and time Usage SETTIME 20yy mm dd hh mm ss...

Reviews: