24
4-2. Communication conditions of serial port
1.When using with baud rate 460800 or above, select "Server" and set High to "CPU
Performance Mode". If baud rate is less than 460800, do not need to set it.
2.Select [Serial Settings].
Set "Protocol" to be "RS-232C" in serial side. Set Baud Rate, Data Bits, Parity,
Stop Bits and Flow Control to be same as the target device.
Set "Protocol" to be "RS-232C".
Settings other than “RS232” do not support echo back and line monitoring function.
Please set CTS/RTS (Hardware) at “Flow Control” when you use the line monitoring
function.
Note
3. Click[ OK ] and then click [ Apply Settings ].
4-3. Set up LAN connection mode
LAN protocol
Select [ Connection ].Then select TCP or UDP.
You can setup either one of them.
* If you select UDP protocol, set [ Datagram Type ] to [ 01 ].
Change [ Remote Host ] and [ Remote Port ] if necessary.
Server Mode
If you select TCP protocol set [ Accept Incoming ].
Select Yes to accept incoming connections. (Server mode)
Client Mode
If you select TCP protocol set [ Active Connect ].
Set client mode to send a request of TCP connection to other device.