LINDY KVM Extender C5 Pro Installation and Use
page 10
LOCAL Switch 2
OFF:
Normal operation.
ON:
Set transparent mode. Use this setting if the Extender C5 modules are to be used with KVM switches
that are not manufactured by LINDY Electronics. Cascaded KVM switches often use special signals to
set or identify conditions. In transparent mode, the Extender C5 modules will pass the signals without
attempting to interpret them.
LOCAL Switch 3
OFF:
Microphone input on REMOTE module. Use this setting if a standard mono-channel microphone is
connected to the microphone input on the REMOTE unit.
ON:
Stereo line-in input on REMOTE module. Use this setting if a stereo input is applied to the microphone
input on the REMOTE unit.
LOCAL Switch 4
OFF: Normal operation.
ON:
Suspend operation and reset the LOCAL module. Use this setting momentarily to produce the same
effect as removing and restoring power if incorrect operation has occurred. Return the switch to the OFF
position to allow normal operation to continue.