URRACO 75 D
S
ERVICE GUIDELINES
Managing director
LINDNER
Mobile Shredder GmbH
Industriestrasse 1A
D-99820 Hörselberg / Eisenach
Service hotline:
+49 (0) 36920 - 7269 - 600
Manuel Lindner
Gerhard Buhl
Walter Geiger
Page - 25 - of - 38 -
1.7.-11
Checking the Coolant Level / Changing the Coolant
Only check the coolant level with the engine switched off and when engine and
cooler are cold. At operating temperature, the coolant is hot and under
pressure.
CAUTION: Do not remove the pressure cap of the cooler unless the
temperature is below 50°C. Otherwise high-pressure steam can be released
and cause injuries due to hot coolant.
Procedure:
1. Remove cover sheet with butterfly screws.
2. Remove filler cap. In doing so, take the filler cap off slowly in order to reduce any
possible pressure.
3. Refill coolant.
4. Check the filler cap seal for damage and replace if necessary.
5. Fasten filler cap.
6. Check the cooler fins for contamination and clean if necessary.
7. Mount cover sheet with butterfly screws.
Cleaning the cooling system and changing the coolant must be done in accordance with the
drive engine operating and maintenance instructions.
Cover sheet
Drain socket