5. Pump new oil into the hydraulic circuit using the hand-operated pump until hydraulic oil
comes out of the measuring connection opening on the oil cooler and of the
suction/return filter vent valve.
6. Screw the measuring connection to the oil cooler and close the vent valve on the
suction/return filter.
7. Connect the hydraulic hose of the hand-operated pump to the oil drain plug of the
hydraulic tank and continue to pump oil into the hydraulic circuit until the oil level
reaches the top edge of the sight glass on the hydraulic tank.
8. Remove the hydraulic hose of the hand-operated pump from the oil tank and screw on
the protective cap.
9. Start the shredder and allow the shredding tools to run and actuate fitting functions until
the corresponding functions are performed correctly.
(In so doing, the hydraulic oil is distributed throughout the lines and the system is
deaerated.)
10. Check the oil level again. The hydraulic oil level must be slightly above the centre of the
sight glass. If necessary, top up the hydraulic oil as described in sections 1.7-8 to 1.7-10
Upper
hydraulic pipe
Suction/return filter
with vent valve