Suction filter
To replace the suction filter, proceed as follows:
1. Have the new filter(s) to hand. Filter cartridge type: see Appendix "Modules and spare
parts".
2. Unscrew the old filters from the filter head.
3. Clean the filter head sealing surface. The old sealing ring may still be sticking to the filter
head. If this is the case, remove it carefully.
4. Fill the oil filter with clean hydraulic oil.
5. Apply a thin hydraulic oil film on the filter seal.
6. Screw the filter onto the filter head. Tighten the filters until the seal touches the surface of
the filter head.
7. Tighten the filter by about another half to three-quarters of a turn.
1.7.-7
Replacing the Tank Aeration Filter
The tank aeration filter on the hydraulic tank must be replaced every 500 operating hours.
The type of filter to be used is listed in the Appendix "Modules and Spare Parts”.
Tank aeration filter