CV-655
A-2
A-2
INSTALLATION
TECHNICAL SPECIFICATIONS – CV-655
Volts at Rated Amperes
44
44
Auxiliary Power
See the OPERATION section
for Auxiliary Power
information by model
Amps
650
815
Maximum Open Circuit Voltage
48
Duty Cycle
100% Duty Cycle
NEMA Class I (100)*
60% Duty Cycle
Current Range
70-815
INPUT - THREE PHASE ONLY
OUTPUT
* European models meet IEC974-1 standards.
1Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of the current increases.
RECOMMENDED INPUT WIRE AND FUSE SIZES
Standard
Volatge
230/460/60
230/460/575/60
208/416/60
460/60
575/60
230/400/50/60*
380/500/50/60*
440/50/60
200/400/50/60
415/50/60
Code
Number
10120
10121
10122
10123
10124
10125
10126
10127
10128
10129
100% Duty Cycle
94/47
94/47/38
104/52
47
38
94/54
56/43
49
107/54
52
60% Duty Cycle
116/58
116/58/47
128/64
58
47
116/67
69/53
60
132/67
64
Input Current at Rated Output
RATED OUTPUT
INPUT
VOLTAGE /
FREQUENCY
208
230
416
460
575
200
230
380
400
415
440
500
TYPE 75°C
(SUPER LAG)
OR BREAKER
SIZE (AMPS)
1
200 Amp
175 Amp
90 Amp
90 Amp
70 Amp
200 Amp
175 Amp
100 Amp
100 Amp
90 Amp
90 Amp
80 Amp
TYPE 75°C
GROUND WIRE
IN CONDUIT
AWG(IEC-MM
2
) SIZES
6 (14)
6 (14)
8 (8.4)
8 (8.4)
8 (8.4)
6 (14)
6 (14)
8 (8.4)
8 (8.4)
8 (8.4)
8 (8.4)
8 (8.4)
TYPE 75°C
COPPER WIRE
IN CONDUIT
AWG(IEC-MM
2
) SIZES
40°C (104°F) Ambient
1 (43)
2 (34)
6 (14)
6 (14)
8 (8.4)
1 (43)
2 (34)
6 (14)
6 (14)
6 (14)
6 (14)
8 (8.4)
INPUT AMPERE
RATING ON
NAMEPLATE
104
94
52
47
38
107
94
56
54
52
49
43
HERTZ
60
60
60
60
60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
PHYSICAL DIMENSIONS
HEIGHT
27.5 in
699 mm
WIDTH
22.2 in
564 mm
DEPTH
38.0 in
965 mm
WEIGHT
652 lbs.
283 kg.