TERMINAL STRIPS
Terminal strips are available behind the cover panel on
the lower case front to connect wire feeder control
cables that do not have a 14-Pin MS-type connector.
Refer to Figure A.3 for the location of this cover panel.
These terminals supply the connections as shown in
the following Terminal Strip charts. See Auxiliary
Power Table for rating of circuit breaker in 115 VAC
circuit. Remove a plug button from the terminal strip
cover and install an appropriate strain relief clamp for
the cable being used. NOTE: There are two work
sense lead connection points on the terminal strip.
Connect both the work sense lead #21 from the 14 -
Pin connector and #21 lead of the control cable to “-
21” when welding positive polarity or to “+21” when
welding negative polarity.
TERMINAL STRIP 1 (T.S.1)
TERMINAL STRIP 2 (T.S.2)
INSTALLATION
A-8
A-8
CV-655
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Lead No.
Function
75
Output Control
76
Output Control
77
Output Control
1
115 VAC circuit is also present on IEC 974-1 European models.
2
If connecting a feeder cable directly to the terminal strip, Lead #21
from the cable is connected to “-21” on the terminal strip for posi-
tive welding. If welding negative polarity, connect lead #21 to the
“+21” connection point on the terminal strip.
Lead No.
Function
+21 Work
Connection
-21 Work
Connection
2
41 42
VAC
4 Trigger
Circuit
2 (42 VAC)
Trigger Circuit (42 VAC)
31 115
VAC
1
32 115
VAC
1