TROUBLESHOOTING & REPAIR
F-44
F-44
CV-655
This is the typical DC open circuit
voltage waveform generated from a
properly operating machine. Note
that each vertical division represents
20 volts and that each horizontal divi-
sion represents 2 milliseconds in
time. The machine was loaded with a
resistance grid bank. The grid bank
meters read 650 amps at 44 VDC.
Note: Scope probes connected at
machine output terminals: (+) probe
to positive High Inductance terminal,
(-) probe to negative terminal.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep.....2 ms/Div.
Coupling ............................DC
Trigger .........................Internal
TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED
0 volts
2 ms
20 volts