TROUBLESHOOTING & REPAIR
F-11
F-11
CV-655
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Observe Safety Guidelines
TROUBLESHOOTING GUIDE
detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
WELDING PROBLEMS
Poor arc characteristics.
1. Check the three-phase input
line voltage at the machine.
The input voltage must match
the rating plate and reconnect
panel.
2. Check the welding cables for
loose or faulty connections.
3. Make sure the proper welding
procedures are being used.
(Wire feed speed, arc voltage
and wire size)
4. Make sure the positive welding
cable is connected to the cor-
rect positive output terminal.
(Low or High inductance)
1. The capacitor bank may be
faulty. Check or Replace.
WARNING: The liquid elec-
trolyte in these capacitors is
toxic. Avoid contact with any
portion of your body.
2. Perform the
Firing Board Test.
3. Perform the
SCR Bridge Test.
4. Perform the
Main Transformer
Test.
5.
The control board may be
faulty. See the
Control Board
LED Chart.
6.
Check the reactor for “shorts”
or “opens”.
Poor arc striking with semiauto-
matic or automatic wire feeders.
1. Make sure the proper welding
procedures are being used.
(Wire feed speed, arc voltage
and wire size)
2. Check the welding cables for
loose or faulty connections.
1. The capacitor discharge resistor
may be faulty. Check. See
Wiring Diagram.
2. Perform the
Firing Board Test.
3. Perform the
SCR Bridge Test.
4.
The control board may be
faulty. See the
Control Board
LED Chart.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-800-833-9353.