CONNECTING THE LN-8 OR LN-9 TO THE CV-655
(14-PIN MS RECEPTACLE)
1.
Set the POWER toggle switch to the OFF (0) posi-
tion.
2.
Disconnect main AC input power to the CV-655.
3.
Connect the electrode cable from the LN-8 or
LN-9 to the “+” terminal of the welder (High induc-
tance or low inductance as needed). Connect the
work cable to the “-” terminal of the welder.
Reverse this hookup for negative polarity. See
Figure C.4.
NOTE: Welding cable must be sized for the current
and duty cycle of the application.
4.
Connect the control cable between the 14-pin MS
receptacle on the CV-655 and the input cable plug
on the LN-8 or LN-9. See Figure C.4.
5.
Place the OUTPUT CONTROL switch in the
“Remote” position and the OUTPUT TERMINALS
switch in the “Remote” position.
6.
Adjust wire feed speed at the LN-8 or LN-9 and set
the welding voltage with the WIRE FEEDER VOLT-
AGE CONTROL.
CONNECTING THE DH-10 TO THE
CV-655 (14-PIN MS RECEPTACLE)
1.
Set the POWER toggle switch to the OFF (0) posi-
tion.
2.
Disconnect main AC input power to the CV-655.
3.
Connect the electrode cable from the DH-10 to the
“+” terminal of the welder (High inductance or low
inductance as needed). Connect the work cable
to the “-” terminal of the welder. Reverse this
hookup for negative polarity.
NOTE: Welding cable must be sized for the current
and duty cycle of the application.
4.
Connect the DH-10 input cable between the 14-
pin MS receptacle on the CV-655 and the input
cable plug on the DH-10. See Figure C.5.
5.
Place the OUTPUT CONTROL switch in the
“Remote” position and the OUTPUT TERMINALS
switch in the “Remote” position.
6.
Adjust wire feed speed at the DH-10 and set the
welding voltage with the WIRE FEEDER VOLTAGE
CONTROL.
7.
Set the DIP switches on the DH-10 for CV-655.
See the DH-10 Operator’s Manual.
ACCESSORIES
C-9
C-9
CV-655
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
FIGURE C.5 – CV-655 DH-10 CONNECTION
ELECTRODE CABLE
-
+
14 PIN
AMPHENOL
POWER SOURCE
TO WORK
DH-10
WIRE
FEEDER
LINCOLN CV-655
DH-10
INPUT CABLE
ASSEMBLY
9 PIN
AMPHENOL
N.E.