D-3
MAINTENANCE
Replacement Steps:
See Figure D.1 for steps 1-9.
1. Disconnect the extraction fan(s) from the input power.
2. Loosen latches (A) and remove the filter cover (B).
3. Unscrew the knurled nut (C) and remove the filter cover plate (D).
4. Lift the LongLife filter cartridge (E) up and out of the filtration
unit.
5. Remove the prefilter (F).
6. If required by federal, state and/or local regulations and
guidelines, conceal prefilter in appropriate bag, e.g. plastic bag.
7. Clean the filter compartment with an industrial vacuum cleaner
that meets OSHA guidelines for Cr6 housekeeping.
8. Install a new prefilter.
9. Replace the dismounted parts in reverse order.
ACTIVATED CARBON FILTER (OPTION)
Replace the Activated Carbon Filter:
•
When detecting odors and smells; or
•
When it has been damaged.
Replacement Steps:
See Figure D.1 for steps 1-6.
1. Disconnect the extraction fan(s) from the input power.
2. Loosen latches (A) and remove the filter cover (B).
3. Unscrew the knurled nut (C) and remove the filter cover plate (D).
4. Remove the Activated Carbon Filter from the LongLife filter
cartridge.
5. Install a new Activated Carbon Filter.
6. Replace the dismounted parts in reverse order
STATIFLEX
®
200-M
B
A
E
F
A
D
C
FIGURE D.1