A-5
INSTALLATION
STATIFLEX
®
200-M
NOTE: The installation may be made permanent by running two
screws in through the bottom housing against the mounting
bracket. See Figure A.6.
6. Replace the filter cover and fasten latches.
7. 8 in. hose gets clamped to the 8 in. side of the reducer with hose
clamp. Then the 6.4” side of reducer goes over the outlet of the
fan and secured with 3 sheet metal screws. See Figure A.7
NOTE: When installing in combination with the SF4200 fan, first
mount flexible outlet with steel bushing (included with SF4200
fan package) on the fan housing.
8. Install the 8 in. sealing ring on the inlet side of the hose.
.
9. Slide the 8 in. diameter connection hose over the sealing ring on
the inlet by placing the hose all the way over the sealing ring.
Secure with a 8 in. diameter hose clamp. See Figure A.8.
In case the filter unit is mounted left of the
SF2400 fan, the SF2400 will be in reverse
position, resulting in centerpoints of fan
outlet and Statiflex 200-M(/HE) inlet not
aligning. This will not affect system performance.
ATTENTION
FIGURE A.7
FIGURE A.8
FAN OUTLET
8 in. DIAMETER
CONNECTION HOSE
8 in. HOSE CLAMP
REDUCER 6.4 in. - 8 in.
FIGURE A.6
8 in. DIAMETER CONNECTION HOSE
INLET