A-7
INSTALLATION
STATIFLEX
®
200-M
3. Using a multi-purpose power saw, cut open both outlets of the
filter cover. See Figure A.12.
4. Secure the mounting bracket to the wall. See Figure A.13.
Fasteners not included.
5. Secure the bottom housing onto the mounting bracket.
See Figure A.13.
NOTE: The installation may be made permanent by running two bolts
in through the bottom housing against the mounting bracket (See
Figure A.13).
6. Replace the filter cover and fasten latches.
7. Install the 8 in. sealing rings on both inlets of the base.
8. Fit the 8 in. diameter connection hoses over the sealing rings on
the inlets and secure them with a 8 in. diameter hose clamp. See
Figure A.14.
9. Fit the other ends of the 8 in. connection hoses over the 8 in.
diameter non-return valves (See Diagram Page F-7) and secure
them with a 8 in. diameter hose clamp. See Figure A.15
NOTE: Be aware of the airflow direction from fan to filter unit. If non-
return valves are installed backwards, airflow will be blocked.
See Figure F-7
10. Fit the 8 in. side of the reducer to the non-return valve and
secure with 3 sheet metal screws. Slide the 6.4 in. side of the
reducer over the outlet of the fan and sealing ring, then secure
with 3 sheet metal screws. See Figure A.16
FIGURE A.12
FIGURE A.14
OUTLET OPENING
FIGURE A.13
8 in. DIAMETER CONNECTION HOSE
INLET
FIGURE A.15
FIGURE A.16
8 in. DIAMETER NON-RETURN VALVE
HOSE CLAMP
HOSE CLAMP
8 in. DIAMETER CONNECTION HOSE
FAN
6.3 - 8 in. REDUCER
8 in. DIAMETER
NON-RETURN VALVE