E-2
TROUBLESHOOTING
STATIFLEX
®
200-M
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR
PROBLEM
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED COURSE OF ACTION
Faulty Filter Maintenance
Indicator. Indicator does not
indicate saturation level of
pre-filter and/or LongLife
filter cartridge.
Blocked indicator tubes.
Clean tubes with compressed air.
Indicator leaking.
Replace Filter Maintenance Indicator.
Poor suction.
Statiflex 200-M(/HE) does not
function properly.
Outlet(s) blocked.
Remove obstructions from the outlet opening(s) and/or
connected ductwork.
LongLife filter cartridge clogged (check filter
maintenance indicator - See Figure B.1).
Remove obstructions from the outlet opening(s) and/or
connected ductwork.
Pre-Filter clogged.
Clean (See Periodic Maintenance) or replace (See Pre-
Filter) the pre-filter.
Dust or smoke coming out of
the outlet opening(s).
Pollution of the facility.
LongLife filter cartridge damaged.
Replace LongLife filter cartridge (See LongLife Filter
Cartridge).
Sealing on LongLife filter cartridge damaged.
Replace LongLife filter cartridge (See LongLife Filter
Cartridge).
Dust or smoke coming out of
the inlet connection(s).
Pollution of the facility.
Outlet(s) blocked.
Remove obstructions from the outlet opening(s) and/or
connected ductwork.
LongLife filter cartridge clogged (check filter
maintenance indicator - See Figure B.1).
Replace LongLife filter cartridge (See LongLife Filter
Cartridge).
Pre-Filter clogged.
Clean (See Periodic Maintenance) or replace (See Pre-
Filter) the pre-filter.
Non-return valve(s) installed incorrectly.
Install non-return valve(s) correctly.
Dust or smoke coming out of
one arm (Dual Arm versions
only). Pollution of the facility.
Related non-return valve installed incorrectly.
Install non-return valve correctly.
Related non-return valve damaged.
Replace non-return valve.
Dust or smoke coming out of
bottom housing. Pollution of
the facility.
Cracks or holes in bottom housing.
Replace bottom housing.