INSTALLATION
For information on installation of fume extrac-
tion arm(s) and extraction fan(s), refer to the
corresponding manuals.
NOTE: Mount the Statiflex 200-M, extraction fan(s) and fume
extraction arm(s) as close as possible to the source of welding.
Use adequate mounting hardware for
installing the unit, corresponding with the
type of wall. Be aware, the weight of the
unit when unpacked is approx. 66 lbs (30
kg). As filter saturates it will increase in
weight.
statiFlex 200-m(/he) single arm
NOTE: In the standard configuration of the Statiflex 200-M(/HE)
Single Arm system, the filter unit is positioned on the right side of
the fan. However, it may be mounted on either side, as long as the
connection hose reaches from the outlet of the fan to the inlet of
the Statiflex 200-M(/HE).
Installation Steps:
If the base is not completely disassembled, it may be
possible that some plastic residue will get stuck in filter
after step 1.
1. Loosen latches and remove the filter cover. See Figure A.2.
2. Using a multi-purpose power saw, cut open through the scribe
mark on the left (or right) inlet of bottom housing; 8 in. (200
mm). See Figure A.3. If using a 6 in. diameter hose, cut open
through the scribe mark on the 6 in. side of the left (or right) inlet
of bottom housing.
3. Using a multi-purpose power saw, cut open one two outlets of
the filter cover See Figure A.4. The outlet shall be on the same
side as the inlet, on base See Figure A.3.
4. Secure the mounting bracket to the wall. See Figure A.5.
Fasteners not included.
5. Secure the bottom housing onto the mounting bracket. See
Figure A.5.
ATTENTION
CAUTION
A-4
INSTALLATION
STATIFLEX
®
200-M
BOTTOM HOUSING
INLET
FIGURE A.2
FIGURE A.3
FIGURE A.4
FIGURE A.5
FILTER COVER
LATCH
OUTLET OPENING
MOUNTING
BRACKET
BOTTOM
HOUSING
FASTENERS
(NOT INCLUDED)