English
English
17
Voltage/Trim Display and Knob
The right display and knob control voltage, trim or output depending upon the process selected. Once welding is
complete, the display continues to show the welding voltage for 5 seconds.
Process Display/Function
Description
SMAW
(Stick) and GTAW
(TIG)
Weld Output
Rotate clockwise to turn output ON.
Rotate counterclockwise to turn output OFF
Non-synergic
GMAW (MIG) and
FCAW Voltage
(Flux-cored)
Voltage
Adjusts the voltage. The display is blank for non-synergic STT modes
Synergic
GMAW (MIG) and
FCAW
(Flux-cored)
Voltage
When the voltage knob is rotated, the display will show an upper or lower
bar indicat ing if the voltage is above or below the ideal voltage. The
display is blank for synergic STT Modes.
Preset voltage above ideal voltage. (upper bar displayed).
Preset voltage at idealvoltage. (no bar displayed).
Preset voltage below idealvoltage. (lower bar displayed)