attempt is made to save a memory when memory saving
is locked, the message "Memory save is Disabled!" will
appear briefly in the display.
A. Recall:
Press
1
second
B. Save:
Press
2
seconds
Limits
Limits allow the welder to adjust the welding procedure
only within a defined range.
Each user memory may have a different set of limits. For
example, memory 1 may limit the WFS to 5 through 7,5
m/min, and memory 2 may limit the WFS to 7 through 8
m/min, while memory 3 may have no WFS limits.
Parameters are constrained by machine limits, or by
setting memory limits. When memory limits are enabled,
the parameter will flash whenever an attempt is made to
exceed the memory limit value. The parameter will not
flash if an attempt is made to exceed the machine limit.
The system machine limits are:
Parameter Range
Units
Wire Feed Speed
Weld mode
dependent and
gear box ratio
dependent
In/min
Voltage Weld
mode
dependent
Volts
Trim 0.50
to
1.50
---
Arc Control
-10.0 to 10.0
Weld
mode
dependent
Preflow 0.0
to
2.5
Seconds
Start Time
0.0 to 10.0
Seconds
Run-In WFS
Off, 50 to 150
in/min
Crater Time
0.0 to 10.0
Seconds
Burnback Time
0.00 to 0.25
Seconds
Postflow Time
0.0 to 10.0
Seconds
Limits may be set for:
Wire Feed Speed/Amperage
Start
Time
Voltage/Trim
Burnback
Time
Arc
Control
Crater Wire Feed Speed
Preflow
Time
Crater
Voltage/Trim
Run-In
Speed
Crater
Time
Start Wire Feed Speed
Postflow
Time
Start
Voltage/Trim
Weld modes cannot be selected through the Limits
Setup menu, and must be chosen and saved to memory
before entering the Limits Setup Menu.
To set limits, press the desired memory button 1-8
and hold for 5 seconds. Release the memory button
when the memory number begins to blink rapidly and
the displays "Memory X Set Limits" as shown below.
A. Set Limits: Press 5 seconds.
If the passcode does not equal zero (0000), enter the
passcode now. If the passcode has been forgotten, a
computer application is required to change the
passcode.
If the passcode has been set to zero (0000), the display
will show the following:
Memory Value
High
Limit
Low
Limit
Parameter
Name
One of these items will flash to indicate which item will
change when the knob is rotated. Press the right button
on to select the item to change.
A. Memory
value
B. High
Limit
C. Low
Limit
D. Press to select item to change
E. Rotate to change value
F. Parameter
Name
The Limits Setup menu shows a list of all parameters
available for the weld mode stored in the memory
chosen. For example, if limits are being set for a stick
(SMAW) mode, parameters such as Run-in WFS and
Postflow will not appear.
To lock a parameter to a specific value that cannot be
changed, set the high and low limits to the same value.