Arc Start/Loss Error Time - This option can be used to
optionally shut off output if an arc is not established, or is lost
for a specified amount of time. Error 269 will be displayed if
the machine times out. If the value is set to OFF, machine
output will not be turned off if an arc is not established nor will
output be turned off if an arc is lost. The trigger can be used to
hot feed the wire (default). If a value is set, the machine output
will shut off if an arc is not established within the specified
amount of time after the trigger is pulled or if the trigger
remains pulled after an arc is lost. To prevent nuisance errors,
set Arc Start/Loss Error Time to an appropriate value after
considering all welding parameters (run-in wire feed speed,
weld wire feed speed, electrical stick out, etc). To prevent
subsequent changes to Arc Start/Loss Error Time, the setup
menu should be locked out by setting Preference Lock = Yes
using the Power Wave Manager software.
OFF (0) to 10.0 seconds (default = Off)
Note:
This parameter is disabled while welding in Stick, TIG or
Gouge.
Joystick Configuration
– this option enables changes of
welding voltage, trim or power in kW and Wire Feed Speed
(WFS) using joyskick in the gun or remote control:
"ON" (default) = change is possible.
"OFF" = change is not possible.
Display Workpoint as Amps Option
– determines how
workpoint is displayed:
"No" (factory default) = the workpoint is displayed in the
format defined in the weld set.
"Yes" = all workpoint values are displayed as an
amperage.
Note:
This option may not be available on all machines. The
power source must support this functionality, or this option will
not appear in the menu.
Feedback Persist
– determines how feedback values are
displayed following a weld:
"No" (factory default)
– last recorded feedback values will
blink for 5 seconds following a weld, then return to
present display mode.
"Yes"
– last recorded feedback values will blink
indefinitely following a weld until a Control or button is
touched, or an arc is struck.
User interface type - determines how the user interface works:
Feeder (FEEd, factory default)
– UI works as Feeder.
STICK/TIG (StIC)
– Dedicated to work UI with a
welding power source (without Wire feeder). UI
allows to set the programs for welding SMAW and
GTAW process.
Note
: STICK / TIG allows to work with an analog wire
feeder also. In this case, additional programs are
avaliable for welding GMAW process in non-synergic
mode.
Parallel (PArA)
– UI works as a remote control.
Parallel may be used only in parallel with the main
panel, which can be set to the "FEEDER" or "STICK /
TIG".
Note:
Selecting the UI type makes restart of system.
Note:
Back to the factory setting forces Feeder type.
Brightness Control - enables the brightness level.
Adjust range: from 1 to +10, where 5 is default.