Note:
After 5 seconds of inactivity will also exit the
Crater Settings Procedure with saving chnages.
Wave Controls
Wave Controls are assigned to the Right
Button.
Note:
The Wave Controls depend on the Welding
Program.
To set the Wave Controls:
Press the Right Button [27] until LED Indicator [26]
will not light
– The Wave Control Settings
Procedure is active.
Use the Right Control [24] to set the Wave Control
value.
The Wave Control value is displayed on the Right
Display [19].
Approve the setting
– use the Right Button [27].
Setting and Configuration Menu
To access the menu, press the the Left [29] and the
Right [27] Buttons simultaneously.
Note:
The Menu cannot be accessed if the system is
welding, or if there is a fault (status LED is not solid
green).
Parameter Selection Mode
– the Parameter Name on
the Left Display [19] blinking.
Parameter Change Value Mode
– the parameter value
on the Right Display [19] blinking.
Note:
To exit the menu with changes saved, press the
Left [29] and the Right [27] Buttons simultaneously.
Note:
After one minute of inactivity the Menu without
saving will also exit.
Table 5. Interface Components and functions when the Settings and Configuration Menu is active.
Figure 8
Functions of Interface Components
19. Left display: Parameter Name.
Right display: Parameter Value.
24. Changing Parameter Value.
27. Entering to Parameters Editing.
Confirm Parameter Value change.
28. Setting and Device Configuration Menu is active.
29. Cancelation / Back.
32. Parameter Selection.
32
29
28
27
24
19