8
Figure 6
Press the Left Button [29] until the LED Indicator [30
or 31] will not indicate the target, the active welding
program.
WARNING
When the input power is switched again on, last welding
process and settings will be recalled.
The assignment of the weld program to the
user memory
In user memory only four welding programs can
be stored.
To assign the weld program to user memory:
Use the Left Button [29] to select the user memory
number (1, 2, 3 or 4) - the LED Indicator [31] will
indicate the selected memory.
Press the Left Button [29] and hold it until LED
Indicator [31] will not blink.
Use the Left Control [32] to select the weld program.
To save the selected program, press the Left Button
[29] and hold it until LED Indicator [31] will be blink.
Warning:
The list of available programs depends on
the power source.
Welding Parameters
Figure 7
From the User Panel the parameters specified in the
Table 4 can be set:
Table 4
Crater
Wave Controls:
Pinch
Frequency
Peak Current
Background Current
Tailout
UltimArc™
ARC FORCE
HOT START
Note:
The availability parameters depend on the
selected welding program.
Crater
Crater Procedure controls the WFS / value in
ampere units and Volts / Trim for a specified
time at the end of the weld after the trigger is
released. During the Crater time, the machine will ramp
up or down from the Weld Procedure to the Crater
Procedure.
The Crater Settings Procedure is assigned to the Right
Button.
Note:
The Crater Settings Procedure will be available if
in the Settings and Configuration Menu the Crater
Procedure (CrAt) is "ON". Otherwise, The Crater
Settings Procedure is ignored.
If the Crater Settings Procedure is available, the Crater
Parameters can be set, such as:
Crater Time
Wire Feed Speed or value in ampere units
The welding voltage in volts units or Trim.
To set Crater for selected program:
Press the Right Button [27].
Crater Settings Procedure Indicator [25] lights.
"SEC" is shown on the Left display.
On the Right Display is blinking value in seconds.
Use The Right Control[24] to set Crater Time
Use The Right Button [27] to confirm Crater Time.
Wire Feed Speed or value in ampere units is shown
on the Left Display [19] and the welding voltage in
volts units or Trim on the Right Display [19].
Use the Left Control [32] to set the value on the Left
Display [19].
Use The Right Control [24] to set the value on the
Right Display [19].
Press the Right Button [27] to confirm the settings.
LED Indicator [25] stops blinking.