7
LINCE ITALIA S.p.A.
2.2 SPECIFICATIONS
9583-GOLD-MST-EN
9582-GOLD-MST-E-EN
Power supply
230 Vac
Battery compartment
max 12 V 18 Ah (Lince item 476LI18-12 not supplied)
max 12 V 7,2 Ah (Lince item 1112LI7,2-12 not supplied)
Power supply
13,8 Vcc 3 A (Lince item 1699LMQ35)
13,8 Vcc; 2 A (Lince item 001505/00052AB-AC)
Transmission frequencies
869.40 MHz-869.65 MHz 1 channel, 868.00 MHz-868.60 MHz 4 channels
FH
Frequency Hopping
TDMA
Time Division Multiple Access
AES
Advanced Encryption Standard
Range
up to 1.5 km in free air (the range depends on the type and the combined device)
Display
Optional
Total wireless devices
up to 64 (between detectors, radio controls, etc.)
up to 32 (between detectors, radio controls, etc.)
Wireless areas
up to 64
up to 32
Wired areas
5 expandable up to 30
5 expandable up to 15
Wireless sirens
up to 64
up to 32
Wireless controls
up to 64
up to 32
NC area 24 h
1 input
Alarm output relay
8 Dual exchange
Arming programs
3
Sectioning
7 different combinations
Open collector outputs
4 programmable (max 100 mA)
Non-volatile events log
512 events
Users
32
Access level
Admin, user, installer
Dimensions:
400x250x100 mm
202x85x357mm
Working temperature
5°C ÷ 40°C
+A +N +NC +C +NA 04 03
V+ D OFF 02 01
W A
UX L2 L1 AS ASE CH BA 12V
L5 L4 L3 A
UX
A
B
C
D
D
D
E
F
E
E
G
H
I
Fig. 2
2.3.1 Components of the 9583-GOLD-MST-EN
CONTROL PANEL
This brief description can be useful in order to identify all the
main parts of the control panel if, for maintenance interventions,
it is necessary to open it.
Table 2
Item
Parts description
A
Mother board
B
Power Supply
C
Battery compartment (not supplied) max 18 Ah
D
Cable passage
E
Wall fixing holes
F
Tubolar vial
G
Fixing holes for expansion cards
H
Ground connection with the cover
I
Plate for tamper proof
2.3 INTERNAL PARTS DESCRITPION