LINCE ITALIA S.p.A.
2.3.6 Description of the terminal blocks (inputs and outputs)
Below is a detailed description of the terminal blocks on the exposed side of the control panel. Tkeep in mind that the numbering of
the terminals goes from top to bottom and from left to right (refer to the previous drawing).
Table 5
TERMINAL
BLOCK
DESCRITPION
+A
•
Stand-by: No voltage (floating terminal block)
•
Alarm: Positive present max. 0.8 A continuous
The relay programming follows; connect a non self-powered siren to this terminal block, which can be used as a
load with SMS command.
+N
•
Stand-by: Positive present max. 0.8 A continuous
•
Alarm: No voltage (floating terminal block)
The relay programming follows; connect a self-powered siren to this terminal block, which can be used as a load
with SMS command.
NA; C; NC
Free relay exchange 10 A programmable via the keypad; can be used as a load with SMS command.
04, 03
Default negative programmable open collector output is associated with the state of alarm K.
The piloting capacity of this output is 80 mA. Can be used as a load with SMS command.
Reference mass, negative power supply (all the masses are common)
V+
BUS power supply
D
BUS data
OFF
The OFF output is a positive present with the control panel disabled, whereas a mass is present when the system
is enabled. The piloting capacity of this output is 80 mA. The polarity can be inverted.
02, 01
Default negative programmable open collector output is associated with the state of alarm K.
The piloting capacity of this output is 80 mA. Can be used as a load with SMS command.
W
Negative output in case of fault, fuse, low battery or power cut; the latter can be programmed
from the keypad as immediate after the failure or 20 minutes after the power cut
Reference mass, negative power supply (all the masses are common)
AUX
Positive always present for powering external devices (detectors, etc.) protected by a fuse that can be reset
Reference mass, negative power supply (all the masses are common)
L2, L1
Freely programmable line inputs and freely connectable to the arming programs
AS
Control panel tamper input line
ASE
AS input to connect external device sabotage
CH
Impulse type input referred to the mass to simultaneously enter programs 1, 2 and 3
BA
Preset self-powered siren battery control input. (Check the presence of the terminal block on the siren). When there
is a mass on this terminal block, the W output is activated
Reference mass, negative power supply (all the masses are common)
12 V
Positive always present for powering external devices (detectors, etc.)
AUX
Positivo sempre presente per l’alimentazione di dispositivi esterni (rilevatori, ecc) protetto da fusibile ripristinabile
Reference mass, negative power supply (all the masses are common)
L3
Freely programmable line inputs and freely connectable to the arming programs
Reference mass, negative power supply (all the masses are common)
L4
Freely programmable line inputs and freely connectable to the arming programs
Reference mass, negative power supply (all the masses are common)
L5
Freely programmable line inputs and freely connectable to the arming programs