22
LINCE ITALIA S.p.A.
Fig. 30
4.7.4 Double technology motion detector storage
The dual technology detector screen (volumetric, curtain, ceiling, etc.) allows you to set the sensitivity of the microwave, the PIR, the
anti-masking and the operating logic. It also allows the association of the latter to one of the three programs or to all three, to set the
operating parameters, times and various attributes, the details of which are shown in the next table.
Table 10 - Double technology detector options
Options
Descriptions
Excluded
The input is excluded or excluded
Silent
If the input is violated, the alarm output is not activated but remains in memory.
Test
The control panel emits a sound whenever the entry is violated
Partializable
The device can be freely associated with the three programs of the control panel
Patrol
With the system enabled, it excludes the input when a key is entered (including a code or remote control) for a certain period
of time. This time can be set in the "times" section.
24 h
The attribute transforms the input into a 24 hour zone
Monitoring
Enable the device to send monitoring signals
LED ON
The detector LEDs remain ON during operation
Delayed
It allows you to set a period of time from the detection within which the system has to be disabled.
Path
If enabled, it is activated only if another input that has the active delay option, detects a presence and follows the same time
duration
A alarm
If active, when the zone is violated, the control panel switches relay A
K alarm
If active, when the zone is violated, the control panel will activate the K output following its programming.
Fire
To be assigned to the input if it is associated with a fire sensor
Bell
The control panel emits a sound when the input is violated, but only when the system is disarmed
Electrolock
If the input is violated, the output with this attribute will be activated for a time set in the time section