21
LINCE ITALIA S.p.A.
Table 8 - Window sensor options
Options
Descriptions
Excluded
The input is excluded or excluded
Silent
If the input is violated, the alarm output is not activated but remains in memory.
Test
The control panel emits a sound whenever the entry is violated
Partializable
The device can be freely associated with the three programs of the control panel
Patrol
With the system enabled, it excludes the input when a key is entered (including a code or remote control) for a certain period
of time. This time can be set in the "times" section.
24 h
The attribute transforms the input into a 24 hour zone
Monitoring
Enable the device to send monitoring signals
LED ON
The detector LEDs remain ON during operation
Delayed
It allows you to set a period of time from the detection within which the system has to be disabled.
Path
If enabled, it is activated only if another input that has the active delay option, detects a presence and follows the same time
duration
A alarm
If active, when the zone is violated, the control panel switches relay A
K alarm
If active, when the zone is violated, the control panel will activate the K output following its programming.
Fire
To be assigned to the input if it is associated with a fire sensor
Bell
The control panel emits a sound when the input is violated, but only when the system is disarmed
Electrolock
If the input is violated, the output with this attribute will be activated for a time set in the time section
Fig. 29
4.7.3 Storing wireless sirens
The siren screen allows you to set the siren volume by choosing from the relative drop-down menu a value between 25% and 100%
in increments of 5%. In addition to this, you can set the type of sound, whether type A or type B, and the other attributes shown in the
table below.
In case of sabotage 24 hours a day with the system disarmed, the relay will trigger anyway but the radio sirens will not start
Table 9 - Siren Options
Options
Descriptions
Monitoring
Enables the device to send supervisory signals
LED ON
If enabled, you can enable the red system status LED to go on
A Alarm
If enabled, the siren is activated when an input with attribute A is violated
K Alarm
If enabled, the siren is activated when an input with attribute K is violated
Local tamper
If the siren is open, the speaker sounds independently of communication with the control panel
Advanced
features
If available on the model in possession it allows to enable the anti-foam, the anti-flame protections and the anti-approximation
Beep
if enabled, the siren emits a brief acoustic alarm each time the system status changes