Instruction Manual for TECH-system type 239
______________________________________________________________________________
Page 34 of 39 june 2020 ver. 09
LINAK Danmark A/S - Mønstedsvej 9 8600 Silkeborg - Telefon 86803611 - www.linak.dk
Power ON
:
This parameter makes it possible to set the control unit to run an automatic
HOME procedure every time voltage is reapplied to the control unit.
The following options are available:
0 = deactivated
1 = activated
{0}
Auto initialisation
:
This parameter sets the starting point for automatic initialisation. The value is
measured in the number of pulses from the innermost position of the
actuator.
The value “0” indicates that the function is deactivated
The following options are available:
0–255
{0}
Dual-hall pulse mode
:
This parameter is used when Dual-hall pulse feedback is applied.
(See also diagram on page 23)
The following options are available:
0 = deactivated
1 = activated
{0}
End stop OUT
:
This parameter is used to limit the stroke length. Enter the number of pulses
that the actuator needs to move to its outermost position. The value “0”
indicates that the function is deactivated
The following options are available:
0–32000
{0}
11
12
13
14