1. Press numeric key 4 to enter ID & RECEIVER SETUP from SETUP MANU.
2. Press numeric key 1 followed by ENT key from ID & RECEIVER SETUP, to select 1st camera/receiver.
(Up to 64 cameras/receiver can be selected. Depend on the model. See MENU shown above)
3. Use blinking cursor to key in data.
Press numeric key 0 followed by ENT setting Priority to 0.
CTRL 1: Not available.
Press numeric key 1 and CTRL2 setting control type to T type.(see notes)
Press numeric key 2 and CTRL2 setting control type to M type.(see notes)
Up to 8 letters can be used for each camera title. To enter camera title, Press F1 to display 26 letters.
Use joystick moving blinking cursor to select desired letter and press ENT
Press ESC when finished.
NOTE:
Joystick can be used to move cursor.
To remove unwanted letter, move cursor to position and press CLR
When camera has higher priority than the monitor, manual camera switching is not possible.
0=highest priority, 2=lowest priority
T and M type control only available when using PIH-820
receiver
T= When CTRL2 is pressed once to turn on relay and CTRL2 pressed again to turn off relay
M= Relay is on when CTRL2 is to pressed and hold. Once CTRL2 is released, relay is turned off.
ALARM SETUP
(Alarm and corresponding Camera)
Matrix contains 64 Alarm inputs, camera with corresponding alarm or preset positions of Fast Dome Camera
can be setup. One Camera may link to multiple alarms any input can trigger any camera and send any specific
dome to any preset. Steps to set up as follows:
1. Press numeric key 5 to enter ALARM SETUP from SETUP MENU.
2. Press numeric key 1 followed by ENT key from ALARM SETUP to select 1st Alarm input.
(Up to 64 Alarm inputs can be set depend on the model, see Menu above)
3. Use blinking cursor to enter data after 1st Alarm input is selected.
Press numeric key 1 followed by ENT key, to set 1st Camera corresponding to 1st alarm Input.
Fast Dome Camera contains 6 Alarm Inputs.
Preset NO: 1 should correspond with 1st alarm input of Fast Dome.
Preset NO: 2 should correspond with 2nd alarm input.
Preset NO: 3 should correspond with 3rd alarm input.
ALARM SETUP
SENSOR POINT
01
CAMERA
1
PRESET NO
007
ENABLE/DISABLE
EN
TYPE < NO/NC >
NO
ALARM SETUP
SENSOR POINT
1
CAMERA
PRESET NO
7
ENABLE/DISABLE
TYPE < NO/NC >
SETUP MENU
1. SYSTEM SETUP
2. SEQUENCE TABLE
3. MONITOR SETUP
4. ID & RECEIVER SETUP
5. ALARM SETUP
6. ALARM TIME SETUP
7. DOME SETUP
ENTER ITEM
5
11