16 sequence tables can be set in this Matrix System. Each sequence table contains 32 positions allowing
set up of 32 cameras and corresponding dwell time. Each SEQUENCE TABLE can be assigned to different
monitors as follows.
Note: Monitor will only display cameras with dwell time set up in each sequence table when GLOBAL DWELL
TIME in MONITOR SETUP is set to 0 sec.
1. Press numeric key 2 to enter SEQUENCE TABLE from SETUP MENU.
2. Press numeric key 1 ,followed by ENT key to enter first sequence table.(1 of 16 tables may be entered)
See MENU shown above.
3. In sequence table, enter Camera ID Number using blinking cursor.
Ex.
Press numeric key 1 ,followed by ENT key(1st camera is set in 1st position). Blinking cursor will
move waiting dwell time to be entered. Press numeric key 3 ,followed by ENT key(dwell time is set
to 3 sec). Blinking cursor will move to 2nd position. Repeat the steps above.
4. Press ESC key to escape from the MENU.
NOTE:
Use Joystick to move cursor.
To clear set up, move cursor to position and press CLR
Each screen will display only 8 sets of information, the system will roll over to the next 8 sets of
data automatically.
Setting Sequence Table
SEQUENCE SETUP
SEQUENCE SETUP
ENTER CABLE No
1
ENTRY CAMERA TIME
ENTER TABLE No
01
ENTRY CAMERA TIME
01
01
03
02
02
05
03
12
03
04
05
06
07
SETUP MENU
1. SYSTEM SETUP
2. SEQUENCE TABLE
3. MONITOR SETUP
4. ID & RECEIVER SETUP
5. ALARM SETUP
6. ALARM TIME SETUP
7. DOME SETUP
ENTER ITEM
2
Setting Monitor
The purpose of Setting Monitor is to assign specific sequence table to corresponding monitor to display
alarm, video loss and CH-Switching as follows.(Each monitor can be assigned 2 sequence tables)
MONITOR SETUP
ENTER MONITOR No
2
SEQUENCE TABLE 1
01
SEQUENCE TABLE 2
03
GLOBAL DWELL TIME
<0 TO 255 SEC.>
02
PRIORITY <0 TO 2 >
0
WARNING DISPLAY
YES
<VIDEO LOSS ALARM>
ENTER MONITOR No
2
SEQUENCE TABLE 1
SEQUENCE TABLE 2
GLOBAL DWELL TIME
<0 TO 255 SEC.>
PRIORITY <0 TO 2 >
WARNING DISPLAY
<VIDEO LOSS ALARM>
SETUP MENU
1. SYSTEM SETUP
2. SEQUENCE TABLE
3. MONITOR SETUP
4. ID & RECEIVER SETUP
5. ALARM SETUP
6. ALARM TIME SETUP
7. DOME SETUP
ENTER ITEM
3
MONITOR SETUP
9