Alarms Setting Menu
After getting in dome setting menu, push joystick down to select <ALARMS>, and then press
key into alarms setting.
1. Display the Alarms Setting Menu
ALARMS
IN1
IN2
IN3
IN4
IN5
IN6
IN MODE
OUT
OUT TIME-OUT
BACK
EXIT
POSI 1
POSI 2
POSI 3
POSI 4
POSI 5
POSI 6
NO
OFF
100 MS
C.SET
CTRL1
Push joystick down to select <IN1> to <IN6>, and then push joystick left or right to select the
connection function:
2. Connection Function of Alarm Input Setting
OFF: NO action.
POSI: Alarm corresponding preset positions mode.
SCAN: Perform auto scan mode.
SEQ.: Perform preset group mode.
TOUR1: Perform tour1 list mode.
TOUR2: Perform tour2 list mode.
PATROL: Perform memory patrol mode.
TRACK: Perform human tracking mode.
(The tracking functions are only for tracking models
ST1254/1258/1304/1308/1354/1358)
Note: 1. When alarm input is tracking mode, if alarm happen, the fast dome camera will
implement the <IN 1> ~ <IN 6>, and then start the tracking function.
2. On tracking mode, once the object move out the traceable or discriminable area, the
fast dome camera will back to the alarm corresponding preset positions 1~6 to
continue doing tracking function after 10 sec..
OFF
POSI
SCAN
SEQ.
TOUR1
TOUR2
PATROL
TRACK
54
Push joystick down to select <IN MODE>, and then push joystick left or right to select <NO>
or <NC>.
NO mode: Contact of input alarm is normally open. If contact is short, alarm will be triggered.
NC mode: Contact of input alarm is normally short. If contact is open, alarm will be triggered.
3. Input of Alarm Mode Setting