RS-485 In/ Out Jack
RS-485 Input (TXDI+, TXDI-) to receiver signal from keyboard, matrix, DVR or multiplexer through twisted
pair cable.
RS-485 Output (TXDO+, TXDO-) sending out signal to next NDC through twisted pair cable.
Recommend Data Cable: 2547 VW-ISC UL 24 AWG x 2C
Transmission Distance: Max. 1 Kilometer
* When 24VAC PSU is used, the recommend cables are:
UL SPT-1 VW-1 18AWG x 2C
UL SPT-2 VW-1 18AWG x 2C
UL SUT 105C VW-1 18AWG x 3C
The distance between 24Vac PSU and fast dome cannot exceed 200 meters.
Ethernet
Standard IEEE 802.3 10 /100 Base-T port
Power/Status LED
Power On: constant red.
Emergency factory default (appendix C): Blinking orange (i.e. red mix with green).
Network LED
Network Link (connected): Constant red.
Networks have activities: Blink red.
Data sent out from server: Blink green.
Network disconnected: Constant slow blinking green.