IF55 ROT CANopen®
WARNING
It is mandatory to set the bit 30 of COB-ID to 1 (value 0 is not allowed).
This means that “No RTR is allowed on the PDO”.
At power on, this object is forced to the default value.
02 Transmission type
[Unsigned8, rw]
Transmission type
PDO transmission
00h (0)
Acyclic, synchronous
not implemented
01h … F0h (1 … 240)
Cyclic, synchronous
implemented
F1h … FBh (241 … 251)
not implemented - reserved
FCh (252)
Synchronous, RTR only
not implemented
FDh (253)
Asynchronous, RTR only
not implemented
FEh (254)
Asynchronous,
manufacturer specific
implemented
FFh (255)
Asynchronous, device
profile specific
not implemented
Default = FEh (cyclic transmission, see hereafter and the
object)
WARNING
Following an attempt to set the
Transmission Type
to 0, the value is
accepted but the PDO message is not sent; following an attempt to
change the
Transmission Type
to any other value that is not supported
by the device, an abort message (abort code = 0609 0030h:
Invalid
value for parameter
) is generated.
If the value next to the
≠
0, the PDO
message is sent cyclically and the interval between two messages is the
time set next to the
object = 0, the PDO message is
not sent.
NOTE
Refer to the “7 - Setting-up” section on page 81 for an example of how the
object is to be set.
MAN IF55 ROT CB E 1.2.odt
6 - CANopen® interface (DS 406)
51 of 88