AMM8A SSI & BiSS C-mode
NOTE
Before starting the calibration and synchronization procedure, please make sure
that the kit IF90-SC is ready to hand.
From the electrical point of view, the kit consists of the following devices:
A) AC-DC power supply, 24V
•
Input Voltage AC min.: 100V
•
Input Voltage AC max.: 240V
•
Output Voltage nom.: 24V
•
Output Connector: 2.5mm x 5.5mm female plug
B) USB cable
•
Standard-A USB plug to a PC Standard-A USB socket
•
Mini-B USB plug to the IF90-SC interface USB socket 2
C) IF90-SC interface and power converter
•
1) Male power jack, 24V Input Voltage, for AC-DC power supply A
•
2) Mini-B USB socket for USB cable B
•
3) 9-pin female D-Sub connector – Not used, available for future use
•
4) 15-pin female D-Sub connector for EXC-D15M-S71-A16-1,0-FCI-S71
cable D
As previously stated, the EXC-D15M-S71-A16-1,0-FCI-S71 cable must be
ordered separately.
D) EXC-D15M-S71-A16-1,0-FCI-S71 cable
•
15-pin male D-Sub connector to the IF90-SC interface D-Sub connector
4
•
14-pin
SQW-107-01-F-D-VS
connector to the modular encoder unit
Refer also to the “5 - Electrical connections” section on page 31.
WARNING
Please note that the IF90-SC interface further provides power conversion to
power the encoder. When you choose the encoder model to connect to through
the software tool (see on page 41) you automatically select also the voltage to
be supplied to the encoder: if you select a wrong model and perhaps a wrong
voltage, irreparable damage could be caused to the device.
6.3 Before launching the calibration and synchronization procedure
Before you start the calibration and synchronization procedure you must follow
the steps below strictly:
•
mount both the code disk and the encoder unit on the motor as
explained in the “4.4 Mounting the encoder and executing the complete
synchronization procedure” section on page 25;
•
disconnect the EC-FCI-LK-TF12-0,5 cable from the 98414-G06-14LF 14-
pin
male
connector of the modular encoder and connect the EXC-
D15M-S71-A16-1,0-FCI-S71 cable D;
MAN AMM8A SSI_BiSS E 1.10.odt 6 - Calibration and synchronization procedure 39 of 80