AMM8A SSI & BiSS C-mode
5 - Electrical connections
WARNING
Power supply must be turned off before performing any electrical connection!
If wires of unused signals come in contact, irreparable damage may be caused
to the device. Thus they must be cut at different lengths and insulated
singularly.
Function
14-pin male connector
TF12 cable
+Vdc
1
1
Brown_Green
0Vdc
2
White_Green
Counting direction
3
Blue
Zero setting / Preset
4
White
CLOCK IN - / MA -
5
Yellow
CLOCK IN + / MA +
6
Violet
DATA OUT - / SLO -
7
Pink
DATA OUT + / SLO +
8
Grey
+5Vdc OUT (100 mA max.)
9
n.c.
Input 1 (reserved)
10
n.c.
B+ (SIN +)
11
Red
A- (COS -)
12
Brown
B- (SIN -)
13
Black
A+ (COS +)
14
Green
n.c. = not connected
1
See the order code for power supply voltage level
1 = +5Vdc ± 5%
2 = +8Vdc +32Vdc
EXAMPLE
AMM8Axx/xxxxx-SC
1
-...
+Vdc = +5Vdc ± 5%
AMM8Axx/xxxxx-SC
2
-...
+Vdc = +8Vdc +32Vdc
MAN AMM8A SSI_BiSS E 1.10.odt
5 - Electrical connections
31 of 80