AMM5A & AMM5B • SSI, BiSS, & RS-485
6. To activate the new Preset value, you must use the
register (set “02” in the
register).
Function
ADDR
DATA Tx
40
01
registers
11
00
12
30
13
24
14
F4
15
00
16
00
17
00
40
00
function in the
register
77
01
function in the
register
77
02
Preset setting enable
[40, wo]
It allows the operator to enable the setting of the
allowed to set a new preset value only after having entered the value “01” next
to this
register. As soon as you have entered the desired
preset value, you must set the value “00” next to this
register and then save data.
Serial number
[44 … 47, ro]
These registers contain the serial number of the device expressed in hexadecimal
notation. They are intended to inform about the year of production, the week of
production and the serial number in ascending order.
The read value must be interpreted as in the following example:
Register
44
45
46
47
Hex
0A
E8
69
EE
Dec
18 30 03630
18 = year of production (first two digits)
30 = week of production (third and fourth digit)
MAN AMM5A_B SSI_BiSS_RS485 E 1.9.odt
6 - BiSS C-mode interface
38 of 56