Page 92 / 107
Section 10. Programmers reference
10.8.15. Save preset
Description
: This command saves the actual analog timing properties for the current
resolution as a preset.
Format
Example
Command {:AF#<in>@SI=<IPS>}
→ {:af#2@si=s}
Response (AF SAVED)CrLf
← (AF SAVED)CrLf
Legend:
<IPS>
Input port selector:
S = Properties will be saved to the current input port.
A = Properties will be saved to all of the input ports.
(This option is reserved for compatibility reasons.)
10.8.16. Delete preset
Description
: This command deletes the desired preset from the analog input port.
Format
Example
Command {:AF#<in>@SI=DEL;<PID>}
→ {:af#2@si=DEL;2}
Response (AF DELETED)CrLf
← (AF DELETED)CrLf
Legend:
<PID>
Preset ID number:
Explanation:
The command deletes the numbered 2 preset.
10.8.17. Delete all presets
Description
: This command deletes all the presets from the analog input port.
Format
Example
Command {:AF#<in>@SI=DEL;255}
→ {:af#2@si=DEL;255}
Response (AF DELETED)CrLf
← (AF DELETED)CrLf
Explanation:
The command deletes all the presets.
10.8.18. Clone preset
Description
: This command clones the desired preset to all of the input ports.
Format
Example
Command {:AF#<in>@SI=CL;<PID>}
→ {:af#2@si=CL;1}
Response (AF CLONED)CrLf
← (AF CLONED)CrLf
Legend:
<PID>
Preset ID number
Explanation:
This command is reserved for compatibility reasons.
10.8.19. List presets
Description
: This command reads and lists all the saved presets from the analog VGA
input port.
Format
Example
Command {:AF#<in>@<S/A>I=LIST}
→ {:af#2@si=list}
Response (AF#<in>:<PID>=
<BL>;<LCF>;<FCL>;<LCVS>;
<SCN>;<VSPP>;<HSPP>;
<VPL>;<HPP>;<VSL>;<HSP>;
<FHSP>;<PHS>
;
)CrLf
(AF END)
←
←
(AF#2:1=
3045;1249;1864;3;
0;1;1;
50;495;1200;1600;
2161;23;)CrLf
(AF END)
Legend:
<S/A>:
Affected ports:
S = single selected input
A = all inputs
<PID>
Preset ID number
<BL>:
(8 x 28.6363M) / fhsync
Summary of Contents for UMX-OPT-TX150R