Section 10. Programmers reference
Page 73 / 107
10.4.2. Change RS-232 baud rate
Description
: The RS-232 baud rate can be set when the BAUD RATE rotary has #0
(software set) state. The command has to be sent with the earlier baud rate but the
response comes with the new baud rate.
Format
Example
Command {RS232BAUD=<rate>}
→ {RS232BAUD=9600}
Response (RS232BAUD=<rate>)CrLf
← (RS232BAUD=9600)CrLf
Explanation:
The device RS-232 port is set to 9600 baud.
Possible settings:
<rate>
Baud rate
9600
9600 baud
19200
19 200 baud
38400
38 400 baud
57600
57 600 baud (default)
115200
115 200 baud
10.4.3. Query RS-232 baud rate
Description:
The RS-232 baud rate can be checked. It works via RS-232 as well, but if it
is used the command has to be sent with the appropriate baud rate.
Format
Example
Command {RS232BAUD=?}
→ {RS232BAUD=?}
Response (RS232BAUD=<rate>)CrLf
← (RS232BAUD=57600)CrLf
Legend:
Please read section
10.4.2
on page
73
.
Explanation:
The device communicates with 57600 baud on the RS-232 port.
10.4.4. Reload factory defaults
Description
: Factory default settings can be reloaded for different functions separately.
Multiple functions can be entered.
Format
Example
Command
{FACTORY=<f1>;<f2>;…;<fx>} → {factory=xpoint;iocards;edidmem}
Response
(FACTORY●<f1>…)CrLf
(FACTO
RY●<f2>…)CrLf
…
(FACTORY●<fx>…)CrLf
←
←
←
(FACTORY XPOINT…)CrLf
(FACTORY IOCARDS…)CrLf
(FACTORY EDIDS…)CrLf
Legend:
<f1>, <f2>
are the names of the functions which have to be reset to factory
default. Any number of <fx> can be entered, separated by semicolons.
<fx>
Restores factory settings to
Additional response
XPOINT
Crosspoint table and configuration
none
GENERAL Elevelsend, RS-232 working mode, baud rate
none
IOCARDS
All I/O settings
none
EDIDMEM Clear User and Dynamic EDIDs
(DE_OK)
(E_SW_OK)
…
(E_SW_OK)
ALL
Restores all of the factory settings listed above
none