Page 88 / 107
Section 10. Programmers reference
10.8.4. Query analog timing properties
Description
: Check analog timing data of the input ports.
Format
Example
Command {:ANALOG#<in>@<S/A>I=?}
→ {:analog#2@si=?}
Response (ANALOG#<in>@<S/A>I=
<PHS>;<FHS>;
<HS>;<VS>;
<HP>;<VP>;
<LCF>;
<FORM>;<VSP>;<HSP>;<FPS>
)CrLf
← (ANALOG#2@SI=
0;2160;
1600;1200;
455;41;1242;
P;+;+;60;)CrLf
Legend:
Please read section
10.8.3
on page
87
.
10.8.5. Reset analog timing properties
Description
: This command resets the analog timing properties.
Format
Example
Command {:ANALOG#<in>@<S/A>I=RESET}
→ {:analog#2@si=reset}
Response (ANALOG#<in>@<S/A>I=
<PHS>;<FHS>;
<HS>;<VS>;
<HP>;<VP>;<LCF>;
<FORM>;<VSP>;<HSP>;<FPS>)CrLf
← (ANALOG#1@SI=
0;2160;
1600;1200;
455;41;1242;
P;+;+;60;)CrLf
Legend:
Please read section
10.8.3
on page
87
.
10.8.6. Set analog color properties
Description
: Set analog color properties data of the input ports.
Format
Example
Command {:PICTURE#<in>@<S/A>I=
<DF_CHA>;<DF_CHB>;<DF_CHC>;
<G_CHA>;<G_CHB>;<G_CHC>;
<O_CHA>;<O_CHB>;<O_CHC>;
<CONT>;<SAT>;<BRIGHT>;<HUE>;)
→ {:picture#2@si=
1023;1023;1023;
1023;1023;1023;
1023;1023;1023;
128;128;0;0;)CrLf
Response (PICTURE#<in>@<S/A>I=
<DF_CHA>;<DF_CHB>;<DF_CHC>;
<G_CHA>;<G_CHB>;<G_CHC>;
<O_CHA>;<O_CHB>;<O_CHC>;
<CONT>;<SAT>;<BRIGHT>;<HUE>;)CrLf
← (PICTURE#2@SI=
1023;1023;1023;
1023;1023;1023;
1023;1023;1023;
128;128;0;0;)CrLf
Legend:
<S/A>:
Affected ports:
S = single selected input
A = all inputs
<DF_CHA>
Digital fine-clamp for CH-A:
0-4096
<DF_CHB>
Digital fine-clamp for CH-B:
0-4095
<DF_CHC>
Digital fine-clamp for CH-C:
0-4095
<G_CHA>
Gain for CH-A:
0-1023
<G_CHB>
Gain for CH-B:
0-1023
<G_CHC>
Gain for CH-C:
0-1023
<O_CHA>
Offset for CH-A:
0-1023
<O_CHB>
Offset for CH-B:
0-1023
<O_CHC>
Offset for CH-C: