Page 22 / 113
Section 2. Controls and connections
2.7.11. Neutrik power connector
Certain MODEX Media connectors are assembled with special Neutrik power connector,
NAC3MPA-1 (Power In). It ensures a very rugged solution in combination with a locking
device in order to guarantee a safe power connection.
Important! PowerCON is a connector without breaking capacity; it should not be connected or
disconnected under load or live!
After plugging it in, turn the plug clockwise; to disconnect, first pull the latch backward, turn
the plug counterclockwise and unplug the connector.
Figure 2-5. Locking and unlocking Neutrik power connector
Supplied power cable
The cable is assembled with NAC3FCA Neutrik power connector (Power In) with white
chuck that fits for thin cables (diameter between 6.0 and 11.0 mm). A black-colored chuck
is also supplied that fits for thick cables (diameter between 9.5 and 15.0 mm).
Assembling
Important! Cable assembling can be only done by qualified person!
If the cable needs to be replaced, the following steps help when assembling:
Step 1.
Put bushing and chuck onto the cable.
Step 2.
Prepare cable.
Step 3.
Insert the wire into the terminals and fasten the clamping device by a flat screw
driver.
Step 4.
Push insert and chuck into housing (pay attention to the guiding keyway!)
Step 5.
Fasten bushing by means of a fork wrench 3/4”, min. Torque 2.5 Nm.
Figure 2-6. Neutrik power connector assembling
2.
3.
2.
1.
23
20
N
L
1
2
3
4
5
1